News:

Please read the Forum Code of Conduct   >>Click Here <<

Main Menu
Menu

Show posts

This section allows you to view all posts made by this member. Note that you can only see posts made in areas you currently have access to.

Show posts Menu

Messages - jayre1965

#1
HO / Re: Bachmann 5 AMP booster troubleshooting
July 03, 2015, 04:01:09 PM
HO scale
#2
HO / Re: Bachmann 5 AMP booster troubleshooting
July 03, 2015, 04:00:42 PM
all DDc power with sound.
#3
HO / Re: Bachmann 5 AMP booster troubleshooting
July 03, 2015, 03:42:43 PM
5 two are doubles = 7
#4
HO / Re: Bachmann 5 AMP booster troubleshooting
July 03, 2015, 02:58:34 PM
Roger T.
             Multimeter - out put with EX Command controller only = 11.29 volts constant to the track with the 5 amp booster I am getting 14.86 volts to the track. EX Command AMPS by it self = 1.7 AMPs and wit the 5 AMP booster I get 1.9 AMPS at the track. 

JayRe
#5
Thanks for the intel ... an issue I have already leaned the hard way.

JayRe
#6
HO / Bachmann 5 AMP booster troubleshooting
July 03, 2015, 01:04:52 PM
Folks I need some assistance here - just purchased a 5 AMP booster from Bachmann for my DCC rail  - - After hooking it up per the instructions - tested the track AMPs and voltage - no change to the power supply. does anyone know how to trouble shoot the 5 AMP booster?

Thanks

JayRe
#7
I am new the DCC world......... First - is it possible to set the power values (1-28 speed settings) with the EZ Command Controller? I purchased two twin locomotives and three singles - one twin runs well with the others I have but the other runs on half power at best. These are brand new out box from factory.
Is there a way to rest the power values with the EZ Command Controller?

Thanks

JayRe